一、SNMP配置

18.3-SNMP原理与配置-下一朵云
图1 路由器配置SNMP

R1配置命令

开启snmp-agent,配置版本,不指定版本默认开启所有

[R1]snmp-agent 
[R1]snmp-agent sys-info version ?
  all  Enable the device to support SNMPv1, SNMPv2c and SNMPv3
  v1   Enable the device to support SNMPv1
  v2c  Enable the device to support SNMPv2c
  v3   Enable the device to support SNMPv3
[R1]snmp-agent sys-info version v2c

配置ACL只允许某个IP的网管软件访问,增加安全性,可选配置

[R1]acl 2000
[R1-acl-basic-2000]rule permit source 192.168.6.110 0

192.168.6.110是网管系统的IP地址

配置读密码和写密码

[R1]snmp-agent community read 123 acl 2000
[R1]snmp-agent community write 456 acl 2000

配置Trap

[R1]snmp-agent target-host trap-hostname esight address 192.168.6.110 udp-port 162 trap-paramsname 789 
[R1]snmp trap enable
Info: All switches of SNMP trap/notification will be open. Continue? [Y/N]:y
[R1]snmp trap source g0/0/0
18.3-SNMP原理与配置-下一朵云
图2 交换机配置SNMP
[SW1]snmp-agent 
[SW1]snmp-agent sys-info version v2c
[SW1]snmp-agent community read 123
[SW1]snmp-agent community write 456

交换机配置Trap

snmp-agent trap enable feature-name ?自定义哪些项目变化时发送告警消息,默认全部开启

[SW1]snmp-agent target-host inform address udp-domain 192.168.6.110 source Vlanif 1 params securityname 789 v2c  
[SW1]snmp trap enable 
[SW1]snmp-agent trap source vlanif 1

community读写密码要不同,否则会被覆盖

二、配置验证

[SW1]dis snmp-agent sys-info 
[SW1]dis snmp sys-info 

三、eSight添加被管理设备

18.3-SNMP原理与配置-下一朵云
图3 NMS添加被管理设备

(1)SNMP模板配置、Telnet模板配置

(2)选择配置好的SNMP模板、Telnet模板

声明:本站所有文章,如无特殊说明或标注,均为本站原创发布。任何个人或组织,在未征得本站同意时,禁止复制、盗用、采集、发布本站内容到任何网站、书籍等各类媒体平台。如若本站内容侵犯了原著者的合法权益,可联系我们进行处理。